Woodward DLE Valve Skid Overhaul

Woodward Gas Valves, Steam Valves and Liquid Fuel Valves

FPES are delighted to be Authorised Service Partners of Woodward Inc and PM Control which allows us to offer Woodward DLE valve skid MRO.

Woodward gas valves, steam valves and liquid fuel valves need routine maintenance to ensure turbine reliability, availability and safe operation.

Refer to the information table below to cross reference which assets you maintain alongside the appropriate OEM service interval guideline.  Reach out to us if you require assistance with identification or maintenance planning for your Woodward DLE valve skid.

Woodward DLE Valve Skid MRO
Woodward DLE Valve Skid MRO

FPES - Woodward DLE Valve Skid MRO

Woodward DLE Valve  Skid MRO Schedule

Woodward Dle Valve Skid Mro Schedule

As recommended by Woodward, an overhaul of the component should be completed when the unit reaches either the Operating Hours or Years in Service interval, whichever comes first. Recommendations are based on normal operating conditions, fuel quality, past maintenance and environment.

Overhauling to Woodward’s factory standards will return the unit to “like-new” condition and allow for another full operating cycle before maintenance is required. Overhauled unit is returned with standard new part warranty of 12 months.

One of our skilled technicians, Alessio working on a Woodward DLE valve skid for a gas turbine application.

Australian and Regional clients now have the value adding ability to keep their Woodward DLE valve skid overhauls local in Australia, saving time and money whilst supporting local industry.

Woodward Aero Derivative Valves

Product Name Operating Hours Years in Service
Hydraulic Control Unit 50,000 hours 6 years
Variable Geometry Hydromechanical Control 50,000 hours 6 years
Variable Geometry Electromechanical Control 50,000 hours 6 years
Variable Stator Vane Actuators 50,000 hours 6 years
1907 Small Liquid Valves 25,000 hours 3 years
1907 Large Liquid Valves 50,000 hours 6 years
Liquid Shutoff Valves 50,000 hours 6 years
LQ25 & LQ25ST Liquid Metering Valves 50,000 hours 6 years
1907 Small Gas Valves 25,000 hours 3 years
3101/3171 Gas Valve with Hydraulic Actuator 50,000 hours 6 years
3101/3171 Gas Valve with Electric Actuator 50,000 hours 6 years
Gas Shutoff Valve 50,000 hours 6 years
GS3/GS10 Gas Metering Valve 25,000 hours 3 years
GS6/GS16 Gas Metering Valve 50,000 hours 6 years
3151 Water Metering Valve 50,000 hours 6 years
CIT/CDP Sensor 50,000 hours 6 years
2057 Pump 50,000 hours 6 years
Electric Gas Metering Valve (EGMV) on LMS100 50,000 hours 6 years
Electric Water Metering Valve (EWMV) on LMS100 50,000 hours 6 years
Electric Liquid Metering Valve (EMLV) on LMS100 50,000 hours 6 years
Variable Bleed Vane (VBV) on LMS100 50,000 hours  

Access to our Woodward Inc technical library here.  We’ll continue to add valuable technical information & project updates in our Resources & Info page.